HK series
Cutting/ grinding liquid chiller
Feature
  • Prevent deterioration of liquid.
  • Open coil type heat exchanger can prevent the obstruction problem of liquid circulating system.
  • Advance the speed of process.
  • Maintain the stability of dielectric fluid, advance the process quality.
  • Avoid fire risk cause by temperature rise and accumulating of dielectric fluid, advance the working safety.
  • Reduce the wastage of electrode.
  • Prevent the spreading of foul odor air, reduce the air pollution.
  • Easy operation and low noise.
  • Made of anticorrosive material.
Control system
Control the coolant temperature with the accuracy of ±0.01K by PID calculation.
Control the coolant temperature with the accuracy of ±1K by ON-OFF of compressor working.
Using DC inverter compressor and inverter control modular which includes energy-saving management can achieve high-accuracy temperature control and intelligent control.
Specification

Opening Dimension Of Oil Tank

Applications

Spindle, Linear Motor, Ball Screw, Grinding Liquid, CNC Cutting System, CNC Lathe, Other Machining Center

Performance Curve